ProductsRelease NotesNewsSolutionsSupportHot Jobs  
   Related Links
      Products
      Analog Front End


  MR Amplifier Revision 5

  Enlarge picture  

 

  > Download PDF Document  

2Gbit/sec Write Data Speed
1.3GHz Read Amplifier Bandwidth

The Guzik MR Amplifier Revision 5 is a next generation of the Guzik head amplifiers. The main advantages of the Guzik MR Amplifier Revision 5 comparing to the Revision 4 are:

  • Fast rise/fall time of the write current (300psec instead of 800psec)
  • Programmable overshoot of the write current up to 100%
  • High bandwidth of the read amplifier (1.3GHz instead of 400MHz)
  • Small write to read recovery time (less than 200nsec comparing to 2µsec)

Read Amplifier

  • Differential voltage sense amplifier
  • Bandwidth: 1.3GHz at -3dB
  • Flatness: ±0.5dB, 0.3 to 1GHz
  • Input noise: less than 0.6 (typical)
  • MR Bias current: programmable -10mA to 10mA in 0.01 mA steps
  • Non-linear distortions (1GHz, 1mV input level): less than 1%
  • Amplification: 30dB*
  • Write to read recovery time: less than 200nsec for both Bias On and Shut Down Bias modes**
  • Guzik MR5 Head Amplifier Compatibility: with Universal Preamplifier UP8 only.

Write Amplifier

  • Write data speed: up to 2Gbit/sec
  • Rise/fall time of write current: (10-90%) 300psec***
  • Programmable overshoot : up to 100% of write current in 1% steps
  • Output common mode voltage: less than ±0.1V
  • Write current: programmable 2mA to 80mA (zero to peak) in 0.02mA steps****
  • Read to write recovery time: less than 40nsec
  • Head voltage swing: more than 12V peak to peak
  • Output impedance: 100Ohm differential

* Required amplification is provided by UP8.

** Measurement conditions: write current 50mA, head inductance 20nH, and write data 1Gbit/sec.

*** Measurement conditions: write current 50mA, 100% overshoot, and L=20nH in series with R=20 Ohm; current probe Tektronix CT-6.

**** Maximum overshoot value in write current range 50-80mA should be calculated according with formula I overshoot + I write = 100mA.

NLTS vs Data Rate

Write Current Waveform

Measurement Conditions:

  • Write Current: 50mA
  • Overshoot Amplitude: 0 to 100%
  • Head Equivalent: 20nH + 20 Ohm


Figure 1A: Write Current, Overshoot 0%


Figure 1B: Write Current, Overshoot 50%


Figure 1C: Write Current, Overshoot 100%



Figure 2A: Write to Read Recovery (Bias On)



Figure 2B: Write to Read Recovery (Bias Shut Down)



Figure 2C: Read to Write recovery


 
 