WITE Revision 1.192 Release Notes
New Hardware Supported
- SSI4910A and SSI4802 PRML chips
- TDA5151, TDA5155, PCA4005, PCA4006 and IBM 36MR04B0C0 head amplifiers
New Features
- Offset operations in Guzik Spinstands are now faster (more than 4 times faster in 312MP). This change
improves testing time for Track Profile and Write/Read offset tests.
- Chip Parameter Optimization Test has been added to WPROF external module (see "Tests"/"Composite
tests"). The test determines optimal value for selected parameter of PRML chip. Simultaneous optimization
of two parameters is also available.
- PRML Automatic Equalization is now implemented for Guzik Clock Recovery patterns in RWA1632
machine. (see "Calibration"/"AutoEqualize"). The procedure selects the appropriate filter in main filter
matrix and performs signal reshaping based on PulseProfile.
- New patterns for peak detection channel allow to write signal up to 320 Mflux and perform parametric
and overwrite measurements. See HFPRM.PDL pattern file.
- Frequency limit in NLTS Spectral Elimination test is extended from 160 to 320 Mflux.
- EEPR4 1:7 Clock Recovery patterns no longer require High Frequency Pattern Generator.
- New 'Set RPM' Test allows users to change RPM dynamically in each zone (see "Tests"/"Composite
tests").
- New Write/Read Offset test has been implemented as a replacement for former "Write/Read offset hook".
(Test module new name: WROFFSET.EXE). New features are: pattern selection, threshold for more
accurate calculation of track center, round-trip profile option, disabling gain adjustment option, etc.
- New test has been added: Monitor Production (see "Tests"/"Production"). This test runs the same
production sequence as Production test, but outputs results into Monitor Database instead of History
Database.
- Operator's identification entered in Operator Panel is now saved between WITE sessions.
- New option in Production test: auto-increment of head serial number can be enabled.
- Track Profile test setup allows users to disable backward profile in order to save test time.
- Unloading radius and unloading RPM can now be specified for Guzik spinstands in WDCP program. (see
"Configure"/"Device"/"Run Alignment Program").
- The frequency for write current calibration can now be specified in "Calibration"/"Current" menu.
- Resolution Delta test now reports the resolution itself in addition to resolution delta.
Bugs Fixed
- If a zone contained several setups then in Production Test setup "Zone enabled" checkbox was not
saved/restored correctly for this zone.
- WSCAN module: if retry is enabled and amplitude error is enabled and amplitude error occurred during
retry, then sometimes this message appeared: "Error 16: No error registered by error file."
- WSCAN module (engineering scanning): Wrong head list was generated in 3 modes: "random", "range"
and "current". This resulted in intermittent error messages during engineering scanning.
- Continuos Write Flux button in Dashboard provided write operation once every 10th revolution
(approximately).
|