WITE Revision 1.43
Release Notes
Introduction
This document contains the release notes for WITE revision 1.43
from Guzik Technical Enterprises. Revision 1.43 is a maintenance
release that fixes bugs involving the overwrite and pulse profile
tests with high-speed patterns, and cartridges with integrated head
amplifiers. Note that WITE 1.43 requires manual updates to be
made to your pattern files.
All discussion in this document uses WITE version 1.42 as a
baseline for comparison. For information about features and
modifications prior to 1.42, please refer to the WITE user’s
manual and to the release notes for previous revisions of WITE.
Bugs Fixed in WITE 1.43
The overwrite test occasionally gave incorrect results when
running in "FastWrite" mode with a high-speed pattern.
This works correctly in WITE 1.43.
The pulse profile test gave incorrect results when used with
high speed patterns. This problem has been fixed in WITE 1.43.
However, some patterns were updated. For this reason, you must
manually copy the HFPRM.PDL and HFPRM.EPT files into every product
directory. Also, if you have created any custom patterns for
the high-speed pattern generator, they should also be modified.
In particular, the pattern definition body should contain the
statement am_length = 0,and the preamble should be a 40
microsecond sequence of 1’s and 0’s which matches those in the
high-speed patterns (e.g. HSD) in the new HFPRM.EPT file.
When a cartridge with an integrated head amplifier was used,
changing zones could result in spurious "TAA recalibration
for head 0 is needed" messages. WITE 1.43 does not produce
these messages.
Known bugs in WITE 1.43
Some bugs were found too late to be fixed for the 1.43 release
and will be fixed in a later release. This section contains all
known bugs that you are likely to encounter. A bug’s presence here
means that we are aware of the problem and actively working to solve
it. If you encounter a problem not on this list, please report it
to Guzik customer support.
The "retest with next setup" option in the
"Production | Grd/Norm" menu does not register
results to the database after the first setup. It should not be
used.
Some DOS applications interfere with communication with Guzik
hardware and can result in unstable test results. Please exit all
DOS applications before running WITE.
|